When upgrading firmware, and I deselect the EEPROM check-box, it will not retain the Z-offset and E-steps.
Not having to record the E-steps and Z-offset will save me a lot of time when flashing 150+ machines in cluster.

Event Timeline

Shawn created this task.May 31 2018, 12:52 PM

Adding to this, the results seem to be a bit scattered. Just based off what I witnessed from flashing G pod in cluster, half of the machines retained their settings, and half did not.

We should be able to run Cura through terminal and post results for each machine, once we get to flashing our next pod.

alexei triaged this task as Normal priority.Jun 12 2018, 8:29 AM
alexei changed the edit policy from "Custom Policy" to "Cura LulzBot Edition (Project)".
alexei added a project: Cura LulzBot Edition.
karrad added a subscriber: karrad.Jun 12 2018, 9:45 AM

Did we have any luck getting logs from these machines?

I think we may have become preoccupied with other projects in cluster, but I will make it a priority to flash a pod tomorrow and get the results posted.

After flashing C pod, I was unable to recreate the original issue. Every machine retained its settings prior to flashing.

Regardless, any time I have to update a pod, I'll make it a point to use Cura through the terminal and record a log.

karrad lowered the priority of this task from Normal to Low.Jun 13 2018, 10:19 AM
karrad claimed this task.

@ZachV Hmm, strange but I guess good to hear? Going to leave this ticket open as a low priority, please update if it pops up again.

karrad closed this task as Resolved.Jul 26 2018, 12:48 PM
karrad removed karrad as the assignee of this task.
karrad added a subscriber: david.hall.

@ZachV @david.hall I am going to close this ticket out, please re-open if it pops up again.