Page MenuHomeAleph Objects Inc

Quiver Profile General Feedback
Closed, ResolvedPublic

Description

Please use this ticket as a general landing spot for profile feedback with Quiver. @anolen will generate tickets for updates as needed.

Please post all feedback on Quiver testing here.
If you notice a specific issue that is common between all tool heads we will split it off as a new ticket to be addressed.

Feedback Checklist:

Have You Already:

-Cleaned the Nozzle off/out?
-Cleaned and/or Sanded the bed?
-Leveled the X axis?
-Restored Failsafe?
-Updated your Firmware?
-Updated your Version of Cura?
-Repeated this error with other machines/toolheads?

Include this Information for R&D Use:

-Error Description
-Machine Type
-Toolhead Type
-Firmware Version
-Cura Version
-Material Being Used
-Estimated age of filament
-Profile being used (please include any profile edits you made, no matter how small)
-STL and/or Gcode (add as file, web link, or shared-j location)
-Environmental Description (enclosed or open air?)
-Pictures (to avoid data issues please remember to compress photos before posting)

Event Timeline

karrad created this task.Dec 17 2018, 9:58 AM
karrad triaged this task as Normal priority.
karrad created this object with edit policy "Cura LulzBot Edition (Project)".

I have noticed with the Hardened Steel Nozzles, the printing temperature needs to be increased 10c-20c in order to get good adhesion. This seems to be the case on all filaments, (only tested PLA and nGen so far) based upon what our profiles are looking like with HS and HS+

anolen updated the task description. (Show Details)Dec 17 2018, 3:53 PM
anolen updated the task description. (Show Details)
anolen updated the task description. (Show Details)
zachah added a subscriber: zachah.Jan 3 2019, 3:09 PM

We don't have a PolyDissolve or PVA profile for Quiver I noticed. I got some good results with PolyDissolve by tweaking some of the PLA profile settings

DaniAO added a subscriber: DaniAO.Jan 3 2019, 3:11 PM

@zachah these have been added with new builds of Cura.

karrad added a comment.Jan 3 2019, 3:19 PM

PVA and Polydissolve were added this morning, 5min re-build after removing distro folder should bring them in. (be sure to clear cache or add a new machine)

karrad added a subscriber: jebba.Jan 11 2019, 1:01 PM

@jebba General profile feedback ticket

jebba added a subscriber: matth.Jan 11 2019, 5:07 PM
In T4918#89648, @karrad wrote:

I have noticed with the Hardened Steel Nozzles, the printing temperature needs to be increased 10c-20c in order to get good adhesion. This seems to be the case on all filaments, (only tested PLA and nGen so far) based upon what our profiles are looking like with HS and HS+

For PLA, I've been having a lot of peeling up issues, whether it's a small <1 hour print or longer ~3 hour print. The current profile has its default printing temp at 195C; I've had a little more success with smaller prints at 205 or 215C, but still have peeling up for bigger prints. Currently trying a a few bigger prints at 225C.

How has Quiver testing been going since the updates a couple weeks ago?

Reminder! Here is the location of the feedback checklist, just in case tis needed 😄
http://devel.alephobjects.com/lulzbot/filament/Testing_Docs_Master/RandD-Testing/feedback-checklist.odt

anolen lowered the priority of this task from Normal to Low.Sep 13 2019, 1:51 PM
karrad closed this task as Resolved.Tue, Dec 3, 10:13 AM