Sensor wires difficult to route to sensor board
Closed, ResolvedPublic

Event Timeline

west created this task.Dec 27 2018, 1:35 PM
west added a comment.Jan 2 2019, 8:30 AM

The sensor wires are a hassle to route behind the filament sensor and have them stay in place.

west moved this task from Report Issues Here to Needs Review on the Quiver board.Jan 2 2019, 8:30 AM
west added subscribers: MikeR, Steven, kent and 2 others.
west added a comment.Jan 2 2019, 10:52 AM

The changes made in this branch are as follows

  • make it easier to keep cables in position when installing the sensor
  • prevent senor cover from bowing when sensor cable cover is installed
west added a comment.Jan 2 2019, 11:07 AM
This comment was removed by west.
kent added a comment.Jan 3 2019, 12:22 PM

The drawing looks good, have these been printed and tested to confirm fitment and that they make it easier to install?

west added a comment.Jan 3 2019, 12:23 PM

@kent I have one on my desk that you can check out

tutley added a comment.Jan 9 2019, 8:01 AM

I installed this yesterday and it is much easier to install and hides the wires better

MikeR added a comment.Jan 9 2019, 8:04 AM

I will agree with @tutley the new covers are much easier to put on and take off.

Steven closed this task as Resolved.Jan 10 2019, 11:58 AM

This is now merged into master.