Page MenuHomeAleph Objects Inc

Red Tags: AS-CB0044 Blower Fan not working due to bad crimps
Open, Needs TriagePublic

Description

I just went through 11 blower flans that were failed out of assembly and I was able to confirm it was due to a bad crimp. Talking with Pre-sub they have been seeing an large amount of these fans failing lately.

Once the bad crimp was removed I was able to get a connection and supply power to the fan. I used two different tests to confirm that these fans were working after cutting off the crimp. I used a multimeter to make sure that the wire had a good connection and followed it up with the MER desktop power supply to confirm that the fans were turning on.

Event Timeline

oliver created this task.Thu, Jan 10, 9:47 AM