This is with .100 firmware and may already be known...

When ever you move the X axis to 300mm, then home it, it tries to go back out to 300mm and it obviously cant go that far so it just keeps going. But also when it does that, it sets the Z to 5mm and once it cant go out to 300mm, it moves the Z down to 5mm and tries again. On a different machine, it just reboot the machine.
Also, the Z can be set to -9mm and that will of course crash the bed trying to go that far down.

Event Timeline

robert created this task.Mar 12 2019, 1:22 PM
robert triaged this task as Normal priority.
robert created this object with edit policy "LulzBot Hardware Products (Project)".
MikeR added a subscriber: MikeR.Mar 12 2019, 2:15 PM

I was able re-creat this issue on both Quiver 8 and 10 once I updated to .100 firmware. I was not able to do this with the older .91 firmware.

MikeR assigned this task to marcio.Mar 12 2019, 3:18 PM

@robert, @MikeR: I was trying to fix the issue where the toolhead will crash if you issue T1 while the head is all the way to the left. However, my attempt to fix the problem seems to have made things considerably worse, so I reverted .101 to the old behavior.

@robert, @MikeR: Please retest with .101. Problem should be resolved there.

EricNugent closed this task as Resolved.Mar 22 2019, 12:13 PM
EricNugent added a subscriber: EricNugent.

Closing ticket, tested and verified the issue was gone off of a few machines in MER operating off of .101 FW